Sign In | Join Free | My burrillandco.com
Home > AC Energy Meter >

Acrel AMB1X0-A-P1 Smart Ac Bus Bar Monitor Start Box And Plug In Box Feeding Detection And Tapping Detection Modules

    Buy cheap Acrel AMB1X0-A-P1 Smart Ac Bus Bar Monitor Start Box And Plug In Box Feeding Detection And Tapping Detection Modules from wholesalers
     
    Buy cheap Acrel AMB1X0-A-P1 Smart Ac Bus Bar Monitor Start Box And Plug In Box Feeding Detection And Tapping Detection Modules from wholesalers
    • Buy cheap Acrel AMB1X0-A-P1 Smart Ac Bus Bar Monitor Start Box And Plug In Box Feeding Detection And Tapping Detection Modules from wholesalers

    Acrel AMB1X0-A-P1 Smart Ac Bus Bar Monitor Start Box And Plug In Box Feeding Detection And Tapping Detection Modules

    Ask Lasest Price
    Brand Name : Acrel
    Model Number : AMB1X0-A-P1
    Certification : CE
    Payment Terms : T/T
    Supply Ability : 5000pc/day
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    Acrel AMB1X0-A-P1 Smart Ac Bus Bar Monitor Start Box And Plug In Box Feeding Detection And Tapping Detection Modules

    AMB Data Center Busway Monitoring Device


    AMB intelligent bus AC monitoring device is a new development to cater for smart power bus bar. It consists of a feeding detection module and a tapping detection module and integrates functions of conventional power measurements, electricity monitoring, consumption assessment and control. It also boasts the online alarm function and enables the independent off-line operation. It monitors the bus bar interface temperature in real time.

    By virtue of 2 RJ45 communication ports (1 in and 1 out) and MODBUS-RTU protocol, it is easy and reliable to upload the monitoring data to the touch screen of the main controller for centralized monitoring, ensuring safe and reliable operation of the system. The smart bus bar monitor has several benefits such as flexible and convenient wiring so that it is a good substitution of the traditional centralized array cabinet.


    Product modules


    ModelStandard functionsOptional functions
    AMB100-A(1) Full electrical measurements of three-phase AC circuit, 2nd to 63rd harmonic measurements, 1 leakage current, 8-way temperature, 1-way humidity, maximum demand measurement, neutral current, potential difference measurement between the null line and the ground line, 2 digital inputs, 2 digital outputs/W(LORA)
    AMB100-A-P1(2) Full electrical measurements of three-phase AC circuit, 2nd to 63rd harmonic measurements, 1 leakage current, 8-way temperature, 1-way humidity,maximum demand measurement, neutral current measurement, 2 digital inputs, 2 digital outputs, discrete auxiliary power supply
    AMB110-A(1) Full electrical measurements of three-phase AC circuit, 2nd to 63rd harmonic measurements, 1 leakage current, 8-way temperature, 1-way humidity,maximum demand measurement, neutral current measurement, potential difference measurement between the null line and the ground line, 2 digital inputs, 2 digital outputs
    AMB110-A-P1(2) Full electrical measurements of three-phase AC circuit, 2nd to 63rd harmonic measurements, 1 leakage current, 8-way temperature, 1-way humidity, maximum demand measurement, neutral current measurement, 2 digital inputs, 2 digital outputs, discrete auxiliary power supply
    AMB1208-way temperature
    AMB120-J8-way temperature, 1 switch output
    AMB10Monitor;the front network port:AMB10(F),the rear network port:AMB10(B&DZ),can automatically display the voltage and current parameters
    AMB10L-72Optional rear network port or bottom network port, can automatically cycle display voltage, current, temperature and other parameters
    AMB20

    AMB20-1:accessory,used with AMB100/AMB110 for network port to network port transfer of intelligent bus staring box and plug-in box

    AMB20-2:accessory,used with AMB100/AMB110 for RS485 port to network port transfer of intelligent bus staring box and plug-in box

    AMB20-3: accessory, used with AMB100/AMB110, used for network port-to-network port transfer of intelligent bus head box and plug-in box.

    AMB20-4: Accessory, used with AMB100/AMB110, used for RS485 port-to-network port conversion of intelligent bus head box and plug-in box.


    Technical parameters

    AMB100-A-□/AMB110-A-□

    Measured parametersVoltage, current, frequency, active power, inactive power, power factor, active energy, inactive energy, 2nd-63rd harmonic, temperature, leakage
    VoltageRated value3x220/380VAC
    Range±20%
    Overloading1.2 times than the rated voltage value continuously or 2 times than the rated voltage value instantaneously per second
    CurrentCT

    AMB100-A:5A/2.5mA, 100A/20mA, 400A/100mA, 600A/100mA

    AMB110-A:100A/20mA

    Range1%-120%
    Overloading1.2 times than the rated current value continuously or 10 times than the rated current value instantaneously per second
    Input frequency45-65Hz
    Measurement accuracyVoltage/current:grade 0.2; active power/energy:grade 0.5; inactive power/energy:grade 1; temperature:±1℃
    Auxiliary power supply

    AMB100/110-A(/W):triggered upon receipt of request signal

    AMB100/110-A(/W)-P1:follow the bus bar voltage

    functionsTemperature detection-20-150℃
    Leakage0-1A
    Digital input2 dry-contact inputs
    Digital output2 relay outputs; contact capacity:3A/30VDC, 3A/250VAC
    CommunicationVia RS485/Modbus-RTU or LORA antenna
    InstallationUse DIN35mm rail
    ProtectionIP20
    Pollution level2
    EnvironmentTemperature/ humidity/ altitude

    Working temperature:-20-60℃

    Storage temperature:-25-70℃

    Relative humidity:≤93%

    Altitude:≤2500m

    SafetyInsulationThe minimum insulation resistance between all terminals and conductive components of the shell is 100MΩ.
    Withstanding voltageWhen a voltage of 2kV AC is applied between the voltage/ current input, relay output, RS485 port, auxiliary power supply and digital inputs, the leakage shall be less than 2mA and no breakdown or flashover shall occur in 1min..
    Electromagnetic immunityElectrostatic discharge immunityClass 4
    Radio frequency electromagnetic immunityClass 3
    Transient burst immunityClass 4
    Surge immunityClass 4

    AMB120

    Measurement accuracyTemperature:±1℃
    Auxiliary power supply220VAC, discrete
    functionsTemperature detection-20-150℃
    CommunicationVia RS485/Modbus-RTU or LORA antenna
    InstallationUse DIN35mm rail
    ProtectionIP20
    Pollution level2
    EnvironmentTemperature/ humidity/ altitude

    Working temperature:-20-60℃

    Storage temperature:-25-70℃

    Relative humidity:≤93%

    Altitude:≤2500m

    SafetyInsulationThe minimum insulation resistance between all terminals and conductive components of the shell is 100MΩ.
    Withstanding voltageWhen a voltage of 2kV AC is applied between the auxiliary power supply and temperature sensors, the leakage shall be less than 2mA and no breakdown or flashover shall occur in 1min..
    Electromagnetic immunityElectrostatic discharge immunityClass 4
    Radio frequency electromagnetic immunityClass 3
    Transient burst immunityClass 4
    Surge immunityClass 4


    Contact us

    Quality Acrel AMB1X0-A-P1 Smart Ac Bus Bar Monitor Start Box And Plug In Box Feeding Detection And Tapping Detection Modules for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Jiangsu Acrel Electrical Manufacturing Co., LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)