Sign In | Join Free | My burrillandco.com
Home > Battery Monitoring System >

Acrel ABAT100-S Lead-acid Battery Monitoring Module For Hospitals And Data Center

    Buy cheap Acrel ABAT100-S Lead-acid Battery Monitoring Module For Hospitals And Data Center from wholesalers
     
    Buy cheap Acrel ABAT100-S Lead-acid Battery Monitoring Module For Hospitals And Data Center from wholesalers
    • Buy cheap Acrel ABAT100-S Lead-acid Battery Monitoring Module For Hospitals And Data Center from wholesalers

    Acrel ABAT100-S Lead-acid Battery Monitoring Module For Hospitals And Data Center

    Ask Lasest Price
    Brand Name : Acrel
    Model Number : ABAT100-S
    Certification : CE
    Payment Terms : T/T
    Supply Ability : 5000pc/day
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    Acrel ABAT100-S Lead-acid Battery Monitoring Module For Hospitals And Data Center

    Battery Online Monitoring System


    ABAT100-HS Collector Module


    Acrel ABAT100 series battery online monitoring system can provide battery operation information such as voltage, internal resistance and internal temperature, including SOC and SOH, and can provide early warning and battery equalization for failed batteries to guarantee battery pack backup time and extend battery pack life. The system has monitoring functions, and is easy to install, maintain and access. The system mainly consists of ABAT100-S single battery monitoring module, ABAT100-C group battery monitoring module, ABAT100-HS collector module and touch screen, etc. The alarm and real-time data can be queried and parameters can be set through the touch screen, and the monitoring platform can be selected to realize networked centralized management.

    Modules for Lead-acid Battery Monitoring System




    Product Module
    ModelFunction Description
    ABAT100-HSDC24V input, one to manage a group of batteries, up to 120 batteries in a group.
    ABAT100-S-02Monitor one 2V battery, monitor battery voltage, internal resistance and negative
    terminal temperature.
    ABAT100-S-06Monitor one 6V battery, monitor battery voltage, internal resistance and negative
    terminal temperature.
    ABAT100-S- 12Monitor one 12V battery, monitoring battery voltage, internal resistance and negative
    terminal temperature.
    ABAT100-CMonitor one charge/discharge current with an ambient temperature with a maximum
    current range of 1000A.

    Dimension


    Technical funcitons



    FunctionDescription
    Online monitoringOnline monitoring 24 hours a day, one battery per module, monitoring voltage, internal resistance and negative terminal temperature;
    High accuracy measurementInternal resistance measurement error as low as 1%;
    Battery internal resistance testAutomatic periodic measurement of the internal resistance of each battery controlled by the collector;
    Low power designManual entry into low power mode, S-module draws current from the battery down to 0.5mA;
    Anti-jamming designHigh anti-interference design, can block the ripple interference of high power high frequency UPS;
    Communication protocolMODBUS-RTU protocol;
    Installation methodTie-down mounting or adhesive mounting;
    Indicator lightRed and green LED lights, green light as the power light, red light as the indicator light;

    Technical parameters



    Technical parametersDescription
    Working Environment

    Operating temperature: -10℃~50℃;

    Relative humidity: 5%~95%;

    Atmospheric pressure intensity: 80~110kPa;

    Monitoring CapabilityOne S-module monitors one battery
    Monitoring Scope2V, 6V, 12V battery with capacity less than 3000AH
    Measurement range and accuracyMeasurement contentScopeAccuracy
    Single Voltage2V, 6V, 12V±0.1%
    Single internal resistance50~65535uΩ(Resolution) 1uΩ
    Negative temperature-5℃~+105℃±1°C

    Power requirements


    Directly from the monitored battery, 2V module normal operation of the absorption current of 10mA, the maximum is not more than 13mA, 6V, 12V module normal operation of the absorption current of 5mA, the maximum is not more than 7mA, different modules absorption current consistency is very high;
    ProtectionMeasuring circuit and power circuit with two levels of protection, with reverse connection protection and opto-isolation;
    Communication InterfaceUART port, support MODBUS protocol
    Insulation withstand voltage2000VAC
    Weight90g

    Network


    Network Solution 1: Touch Screen Serial Port Acquisition Network Solution:


    Network Solution 2: Acrel EMS, EIOT Platform Network Solution:


    Note:

    ABAT100-HS: one manages 1 group of batteries, up to 120 batteries in one group;

    ABAT100-S-02/6/12: Detects 2/6/12V battery, also detects battery voltage, internal resistance and negative temperature;

    ABAT100-C: Detects 1 charge/discharge current and 1 ambient temperature, with a maximum current range of 1000A;


    Photo on site



    Manufacturer Chinese Company


    Contact us


    Quality Acrel ABAT100-S Lead-acid Battery Monitoring Module For Hospitals And Data Center for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Jiangsu Acrel Electrical Manufacturing Co., LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)